KSO Switchgear Cells

KSO Switchgear Cells  

 

камера ксо

Factory-assembled switchgear cells of one-sided maintenance include the following models:  KSO 285, 292, 366, and 386.

 

Application:

The switchgear cells are designed for operation in electrical alternating current three-phase units, with 50 and 60 Hz frequency, 6 kV and 10 kV voltage, used for systems with insulated neutral or neutral earthed via arc suppression coil.

The switchgear cells are manufactured for different sectors of economy. Such cells are used in switchgear devices for receiving and distribution of electrical power. The operation is determined by the pattern of primary and auxiliary circuits of switchgear cells. The cells are suitable for use in temperate climates; placement category 3 according to GOST 15150.

KSO switchgear cells of Series 200 (KSO 205, KSO 285, KSO 292, KSO 299)

- KSO switchgear cells of Series 300 (KSO 366, KSO 386)

The UZTT factory has its own facilities to manufacture high-voltage switchgears and factory-assembled switchgear cells of one-sided maintenance (KSO switchgear cells); it specializes in low and high voltage equipment for power supply systems for industrial facilities, civil construction, agriculture, oil and gas industry, mining industry; it manufactures the following types of cells:

Cells consist of welded metal structure composed of cold-formed steel sheets. Devices and buses for primary circuits are installed inside KSO switchgear cells; the façade side has controls actuated by a load-break switch (VNR: VNA, VNB) and a disconnecting switch (indoor DS with grounding blades or indoor DS with molded insulating bushings and with grounding blades).

Switchgear cells KSO-205 (similar to KSO-285, 292, and 299) are designed for operation in electrical three-phase ac installations with 50 Hz frequency and insulated neutral or neutral earthed via arc suppression coil, with rated voltage 6 and 10 kV.

Standard operating conditions:

- altitude - max 1000 m

- ambient temperature from -40 to +40 С

- relative humidity - max 70%

- in dry heated and unheated enclosed premises; non-explosive environment free of current-conducting dust, aggressive gases or vapors affecting operation of the device

- operating attitude of KSO switchgear cells - vertical; 5 degree tolerance in either direction is allowed.

Description of KSO Switchgear Cells

KSO cell parameters

KSO cell configuration

Insulation level as per GOST 1561.1

Standard insulation

Insulation of primary circuit conduct buses

Bare buses

Busbar arrangement

Single busbar arrangement

Maintenance conditions

One-side maintenance

Type of high-voltage line entrance (connections)

Cable and bus

Protection rating as per GOST 14254

IP20 - for outer façade and lateral sides
IP30 - for side panels of row-end KSO switchgear cells
IP00 - for other parts of KSO switchgear cells

Type of KSO switchgear cells according to installations

Cells with high-voltage circuit breakers (BB/TEL-10, VBE-10) for 630, 1000 А;
Cells with power fuses (PKT-6, PKT-10, PKN-6, PKN-10);
 KSO switchgear cells  with load-break switches;
 KSO switchgear cells with voltage transformers (NOM, NAMI, ZNOL);
KSO switchgear cells with indoor disconnecting switches (indoor DS with grounding blades or indoor DS with molded insulating bushings and with grounding blades) for 630, 1000 А with drives (PR-10);
Cells with cable assembly;
KSO switchgear cells with power transformers (TSKS-10/ 0.4 kV 25 kVA);
Cells with auxiliary devices;
 KSO chambers with valve arresters (RVRD-6U1, RVRD-10U1, RVO-6, RVO-10) and condensing units;
Cells with arresters or surge protection devices (SPD-6, SPD-10).

Basic parameters of factory-assembled KSO switchgear cells, Series 200

KSO cell parameter

switchgear cell KSO - 205

Rated voltage (line), kV

6; 10

Rated operating voltage (line), kV

7.2; 12

Rated current of primary circuits of cells with vacuum circuit-breaker, А

400; 630; 1000

Rated breaking current of KSO cells with vacuum circuit-breaker, kA

12,5; 20

Rated breaking current of cells with vacuum circuit-breaker (short-time current), kA

12.5; 20

Current of electro-dynamic stability of cells with vacuum circuit-breaker, kA

32; 52

Rated current of primary circuits of cells with oil circuit-breaker at frequency 50 HZ, kA

630; 1000

Rated breaking current of KSO cells with oil circuit-breaker (short-time current), kA

20

Thermal stability current of cells with oil circuit-breaker (short-time current), kA

20

Current of electro-dynamic stability of cells with oil circuit-breaker, kA

52

Flow time of 1000 А thermal stability current, sec:
- for KSO cells with vacuum circuit-breaker  
- for KSO cells with oil circuit-breaker

33

Rated current of transformers for KSO switchgear cells,  А

50; 100; 150; 200;
300; 400; 630; 800; 1000

Rated current of cell bus bars, А

630; 1000

Rated voltage of auxiliary circuits of KSO cells, V:


- dc and ac circuits of protection and alarm control, V
- circuits of voltage transformers, V
- circuits of auxiliary transformers, V

220
100
220; 380

KSO cell light circuits:


- inside the cell, V

12; 36; 42

- outside the cell, V

220

Fuse link current, А

2; 3,2; 5; 8; 10; 16; 20; 31,5...160

KSO switchgear cells are made using:

- diagrams of primary circuits (primary connections);
- diagrams of auxiliary circuits.

Depending on a primary circuit, the cell can be equipped with:

  1. Oil and vacuum circuit-breakers (VPMP, VMPE, VMG, BB/TEL; VVTE and others) for 630, 1000 А;
  2. Indoor disconnecting switches for 630, 1000 А with drives (PR-10);
  3. Disconnecting switches (indoor DS with grounding blades or indoor DS with molded insulating bushings and with grounding blades) for 630, 1000 А with drives (PR-10);
  4. Current transformers (type TOL-10, TPOL-10) for 50 , 75, 100, 150, 200, 300, 400, 600, 800, 1000 А;
  5. Voltage transformers (type NOM, NAMI, 3х3NOL);
  6. Fuses (type PKT6, PKT10, PKN6, PKN10);
  7. Surge protection devices (type SPD-10, SPD-6);
  8. Power transformers (TSKS-40, TM-25, TM-40);
  9. Valve arresters (RVRD-6U1, RVRD-10U1, RVO-6, and RVO-10).

Application of KSO switchgear cells; basic parameters of factory-assembled KSO switchgear cells, Series 300

Switchgear cells KSO -305, with 6-10 kV voltage, are designed for three-phase ac 50 Hz distribution devices of systems with insulated neutral. These cells are installed in enclosed premises of transformer substations and in equipment rooms, and are cells of one-side maintenance.  They are fixed to each other with bolts. Cells are based on primary connection circuits. They are equipped with load-break switches (VNP-M1-10 or VNA-10) with drives (PR-10 or PR-17), disconnecting switches (indoor DS with grounding blades), valve arresters and other high-voltage devices, depending on the circuit.

In their relative position, KSO switchgear cells of Series 300 are made as single-row or double-row cells. In addition to packaged devices, the order can include end plates and, in case of double-row cells, busbar bridges.

Packaged switchgears assembled from 300-series cells are distinguished by smaller dimensions, amount of metal and weight.

The high-voltage cell assembly ready for delivery includes:

  1. KSO switchgear cells, components and parts;
  2. Busbar bridges - at request;
  3. Spare parts and tools in accordance with the Tools & Accessories List.

The delivery includes the following documentation:

  1. Operation manual for KSO switchgear cells;
  2. Operation manual for main components that require electric diagrams for primary circuits cells;
  3. Electric and wiring diagrams for auxiliary circuits;
  4. Tools & Accessories List;
  5. Certificate of Conformity for KSO switchgear cells.

    Price for KSO Switchgear Cells in rubles, including an 18% VAT

    1

     KSO - 366 -1, 386

    41 500

    2

     KSO - 366 -2, 386

    46 600

    3

    KSO - 366 -3, 386

    51 700

    4

     KSO - 366 -4N, 386

    44 900

    5

     KSO - 366 -5N, 386

    75 500

    6

    KSO - 366 -6N, 386

    95 900

    7

     KSO - 366 -7N, 386

    50 000

    8

     KSO - 366 -8N, 386

    70 400

    9

     KSO - 366 -9N, 386

    90 800

    10

     KSO - 366 -10, 386

    81 600

    11

     KSO - 366 -11, 386

    123 100

    12

     KSO - 366 -12, 386

    49 100

    13

     KSO - 366 -13, 386

    51 700

    14

     KSO - 366 -14, 386

    21 100

    15

     KSO - 366 -15, 386

    21 100

    16

     KSO - 366 торцевые КСО 386

    1 500

    KSO - 285 with the vacuum switch VBSK

    17

     KSO 285 -1 VV-600

    268 000

    18

     KSO 285 -2 VV-600

    280 000

    19

     KSO 285 -3 VV-600

    268 000

    20

     KSO 285 -4 VV 600

    280 000

    21

     KSO 285 -5 VV 600

    265 000

    22

     KSO 285 -6 VV 600

    277 000

    23

     KSO 285 -7 VV 600

    301 000

    24

     KSO 285 -8 VV 600

    268 000

    KSO - 285 with the vacuum switch BB/TEL

    25

     KSO 285 -1 VV-600

    308 000

    26

     KSO 285 -2 VV-600

    320 000

    27

     KSO 285 -3 VV-600

    308 000

    28

     KSO 285 -4 VV-600

    320 000

    29

     KSO 285 -5 VV-600

    305 000

    30

     KSO 285 -6 VV-600

    317 000

    31

     KSO 285 -7 VV-600

    341 000

    32

     KSO 285 -8 VV-600

    308 000

    KSO - 285

    33

     KSO 285 -9-400

    51 700

    34

     KSO 285 -10-400

    75 500

    35

     KSO 285 -11-400

    116 300

    36

     KSO 285 -12-600

    128 200

    37

     KSO 285 -13-400

    118 000

    38

     KSO 285 -14-400

    125 000

    39

     KSO 285 -15-400

    97 600

    40

     KSO 285 -16-400

    97 600

    41

     KSO 285 -18-600

    128 200

    42

     KSO 285 -19-600

    128 200

    43

     KSO 285 -20-400

    102 700

    44

     KSO 285 -22-600

    61 500

    45

      KSO 285 -23-600

    61 500

    46

     KSO 285 -24-600

    41 500

    47

     KSO 285 -25-600

    128 200

    48

     KSO 285 -26-600

    51 700

    49

     KSO 285 -27-600 (reserve)

    54 100

    50

     KSO 285 -28

    40 500


To make an order, please, fill in the DATA SHEET for KSO Switchgear Cells units

Russian version of KSO Switchgear Cells

Operating time: round the clock, every day
Phone in Ekaterinburg +7 (343) 310-04-40, Phone in Chelyabinsk +7 (351) 240 -02-84
Phone in Moscow +7 (495) 661-31-01, Phone in St.Petersburg +7 (812) 600-36-31
E-mail: uztt@mail.ru ICQ: 350 974 476 | 576 906 550
Rambler's Top100 Яндекс цитирования